Wear-resistant thermocouple parameters
Wear-resistant thermocouple parameters
1. Application of wear-resistant thermocouple
It is suitable for occasions where the protective tube is severely worn, such as power plant ball mills, coal mills, etc.2. The main technical parameters of wear-resistant thermocouples
Electrical outlet: M20x1.5, NPT1/2Hardness of wear-resistant head: HRC62-65
Protection level: IP65
3. Models and specifications of wear-resistant thermocouples
Model number | Index number | Temperature measurement range ℃ | Nominal pressure | Flow rate | specification | |
d | Lxl mm | |||||
WRN-230NM WRN2-230NM |
K | 0-800 | ≤10MPa | ≤100m/s | Φ16 |
300x150 350x200 400x250 450x300 500x350 550x400 650x500 900x750 1150x1000 |
WRE-230NM WRE2-230NM |
E | 0-600 | ||||
WZP-230NM WZP2-230NM |
Pt100 | -200-+500 | ||||
WRN-630NM WRN2-630NM |
K | 0-800 | ≤30MPa | ≤80m/s | Φ15 | |
WRE-630NM WRE2-630NM |
E | 0-600 | ||||
WZP-630NM WZP2-630NM |
Pt100 | -200-+500 |
2) The material of the protection tube is 1Cr18Ni9Ti, and the other materials are ordered according to the agreement.