Thermocouple for power station
Thermocouples for power stations include: thermocouples for furnace roof, thermocouples for flue ducts, Special wear-resistant thermocouple for circulating fluidized bed power plant
It is suitable for the roof of power plant boilers and other occasions requiring long-distance, high-pressure temperature measurement.
2. The main technical parameters of the thermocouple
Electrical outlet: M16x1.5
Connection size: M16x1.5
Protection level: IP65
3. Types and specifications of thermocouples
1) Thermocouple Class I is ordered according to agreement
2) The material of the protection tube is 1Cr18Ni9Ti, and the other materials are ordered according to the agreement.
2. The appearance structure of the flue thermocouple
Thermocouple for furnace top
1. Application of thermocoupleIt is suitable for the roof of power plant boilers and other occasions requiring long-distance, high-pressure temperature measurement.
2. The main technical parameters of the thermocouple
Electrical outlet: M16x1.5
Connection size: M16x1.5
Protection level: IP65
3. Types and specifications of thermocouples
Model number | Index number | Temperature measurement range ℃ | Nominal pressure | Flow rate | Specification (mm) | |
L | l | |||||
WRN-0313T WRN2-0313T |
K | 0-800 | ≤30MPa | ≤100m/s |
1000 2000 3000 4000 5000 6000 8000 10000 15000 20000 25000 |
50 100 150 |
WREK-0313T WREK2-0313T |
E | 0-600 | ||||
WRNK-0913T WRNK2-0913T |
K | 0-800 | ||||
WREK-0913T WREK2-0913T |
E | 0-600 |
2) The material of the protection tube is 1Cr18Ni9Ti, and the other materials are ordered according to the agreement.
Flue thermocouple
1. Technical parameter table of thermocouple of flueThermocouple indexing number | Temperature measuring element | Diameter of outer protective sleeve | Operating temperature | Material of outer sheath | Length L/l | Process connection | Remarks |
K E Pt100 |
Recommend double thermocouple | Φ28 | 0~800℃ | 1Cr18Ni9Ti或316 |
480/230 680/430 880/630 1380/1130 |
R2-in 2-in.NPT |
The temperature measurement of the flue gas duct adopts a thermocouple sprayed with a wear-resistant protective sleeve Wind temperature measurement adopts stainless steel protection tube thermocouple |