1. Application of assembling thermocouple
It is usually used in conjunction with display instruments, recording instruments, and electronic calculations. It is directly used to measure the surface temperature of liquid, steam and gas medium and solid surface in the range of 0°C~1300°C in the production process.2. Features of assembling thermocouple
• Simple assembly and easy replacement• Compression spring type temperature sensing element, good anti-vibration performance;
• Large temperature measurement range
• High mechanical strength, good pressure resistance
3. The working principle of assembling a thermocouple
The electrode of the thermocouple is composed of two different conductor materials. When there is a temperature difference between the measuring terminal and the reference terminal, a thermoelectric potential will be generated, and the working instrument will display the temperature value corresponding to the thermoelectric potential.4. The main technical parameters of the assembled thermocouple
Product implementation standardsIEC584
IEC1515
GB/T16839-1997
JB/T5582-91
5. Normal temperature insulation resistance of assembled thermocouple
The ambient temperature of the thermocouple is 20±15°C, and the relative humidity is not more than 80%. The test voltage is 500±50V (DC). The insulation resistance between the electrode and the outer tube is >1000Ω.m.6. Measuring range and tolerance
Model number | Index number | Tolerance-grade | |||
I | II | ||||
Tolerance value | Temperature measurement range °C | Tolerance value | Temperature measurement range °C | ||
WRN | K | ±1.5°C | -40~+375 | ±2.5 °C | -40~+333 |
±0.004ltl | 375~1000 | ±0.0075 ltl | 333~1200 | ||
WRM | N | ±1.5°C | -40~+375 | ±2.5°C | -40~+333 |
±0.004 ltl | 375~1000 | ±0.0075 ltl | 333~1200 | ||
WRE | E | ±1.5°C | -40~+375 | ±1.5°C | -40~+333 |
±0.004 ltl | 375~800 | ±0.004 ltl | 333~900 | ||
WRF | J | ±1.5°C | -40~+375 | ±1.5°C | -40~+333 |
±0.004 ltl | 375~750 | ±0.004 ltl | 333~750 | ||
WRC | T | ±1.5°C | -40~+125 | ±1°C | -40~+133 |
±0.004 ltl | 125~350 | ±0.0075 ltl | 133~350 |
8. The naming method of the model
9. Model and specifications
10. Wiring method
11. Selection table of assembled thermocouple
Thermocouple without fixing device, selection list
|
Fixed thread thermocouple, selection list |
Movable flange thermocouple, selection list | Fixed flange thermocouple, selection list |
Fixed thread cone thermocouple, selection list | Active pipe joint thermocouple, selection list |
Straight pipe joint thermocouple, selection list | Fixed threaded joint thermocouple, selection list |
Movable threaded pipe joint thermocouple, selection list |