Industrial high temperature and high pressure thermocouple
Industrial high temperature and high pressure thermocouple
1. Application of high temperature and high pressure thermocouple
It is suitable for temperature measurement and control in high temperature and high pressure places in the production process of petroleum and chemical industry. It is a commonly used temperature device in oil refineries and high-pressure polyethylene.2. The main technical parameters of high temperature and high pressure thermocouple
Electrical outlet: M20x1.5, NPT1/2Connection size: M20x1.5, NPT1/2
Protection level: IP65
Explosion-proof grade: d‖BT4, d‖CT5
Nominal pressure: 15-40MPa
3. Models and specifications of high temperature and high pressure thermocouples
Model number | Index number | Temperature measurement range ℃ | Thermal response time | Material of protection tube | Specification Lxl |
WRNG-430 WRN2G-430 |
K | 0-800 | <180S | 1Cr18Ni9Ti |
380x150 430x200 480x250 530x300 580x350 630x400 680x450 |
WREG-430 WRE2G-430 |
E | 0-600 | |||
WRNG-440 WRN2G-440 |
K | 0-800 | |||
WREG-440 WRE2G-440 |
E | 0-600 |
The remaining materials of the protection tube are ordered according to the agreement;
Model 430 is waterproof, and model 440 is explosion-proof.
4. Protection tube material and selection
Material | Use temperature °C | Features and uses |
1Cr18Ni9Ti | -200—800 | Has high temperature corrosion resistance, usually used for general heat-resistant steel |
304 | -200—800 | Low carbon content, good intergranular corrosion resistance, usually used as general heat-resistant steel |
316 | -200—750 | Low carbon content, good intergranular resistance, usually used as heat-resistant steel |
316L | -200—750 | Ultra-low carbon content, good intergranular corrosion resistance, usually used as heat-resistant steel |
310S | -200—1000 | Has high temperature oxidation resistance, corrosion resistance, usually used as heat-resistant steel |
GH3030 | 0—1100 | Nickel-based superalloy steel has excellent oxidation resistance and corrosion resistance, and is usually used as heat-resistant steel |
5. Casing type selection
The flange can choose 900 (PN15)-2500LB (PN40) RJ and other different forms.6. Flange model and specification of high temperature and high pressure thermocouple
Flange standard codeStandard code | File Number |
China National Standard | GB9112-9131-88 |
China Ministry of Chemical Industry Standards |
HG20592-20635-97 |
China Ministry of Machinery Standards |
JB/T74-90-94 |
American standard | ASME/ANSI B16.5-88 |
German standard | DIN 2628-2638-1975 |
Japanese standard | JIS2201-1796 |
7. Flange specifications
CLASS150-600 RFCLASS900-2500 RJ
8. Type selection instructions
modelIndex number
Accuracy class
Protection tube material and form
Flange specification and form
Length or insertion depth
Example A: High temperature and high pressure flameproof thermocouple type K, level 1, protection tube type A, insertion depth 300mm. WRNG-440A L×1=450×300 mm. dⅡBT4 316L ANSI 1″1500#RJ
Code | N | M | D | d | D1 | D2 |
A | M20x1.5(NPT1/2) | NPT1″ | Φ34 | Φ9 | Φ23 | Φ18 |
B | NPT11/4″ | Φ45 | Φ9 | Φ28 | Φ23 |