Armored thermocouple parameters
1. Application of armored thermocouple
It is usually used in conjunction with display instruments, recording instruments, and electronic computers. Directly measure the surface temperature of liquid, steam and gaseous media and solids in the range of 0°C~1300°C during the production process.
2. Features of armored thermocouple
Short thermal response time, reducing dynamic error;Can be bent for installation and use;
Large measuring range;
High mechanical strength and good pressure resistance;
3. The working principle of armored thermocouple
The electrode of the armored thermocouple is composed of two different conductor materials. When there is a temperature difference between the measuring terminal and the reference terminal, a thermoelectric potential will be generated, and the working instrument will display the temperature value corresponding to the thermoelectric potential.
4. The main technical parameters of the armored thermocouple
Product performance standardsIEC584
IEC1515
GB/T16839-1997
JB/T5582-91
5. Measuring range and tolerance of armored thermocouple
Model number | Index number | Tolerance class | |||
I | II | ||||
Tolerance value | Temperature range °C | Tolerance value | Temperature range °C | ||
WRNK | K | ±1.5°C | -40~+375 | ±2.5°C | -40~+333 |
±0.004ltl | 375~1000 | ±0.0075ltl | 333~1200 | ||
WRMK | N | ±1.5°C | -40~+375 | ±2.5°C | -40~+333 |
±0.004ltl | 375~1000 | ±0.0075ltl | 333~1200 | ||
WREK | E | ±1.5°C | -40~+375 | ±1.5°C | -40~+333 |
±0.004ltl | 375~800 | ±0.004ltl | 333~900 | ||
WRFK | J | ±1.5°C | -40~+375 | ±1.5°C | -40~+333 |
±0.004ltl | 375~750 | ±0.004ltl | 333~750 | ||
WRCK | T | ±1.5°C | -40~+125 | ±1°C | -40~+133 |
±0.004ltl | 125~350 | ±0.0075ltl | 133~1000 | ||
WRPK | S | ±1°C | 0~+1100 | ±2.5°C | 0~600 |
±[0.003(t-1100)] | 1100~1600 | ±0.0025ltl | 600~1600 |
6. Insulation resistance at room temperature
Galvanic armor at an ambient temperature of 20 ± 15 ° C, relative humidity less than 80% of the test voltage of 500 ± 50V (DC). The insulation resistance between the electrode and the outer sleeve>1000MΩ. That is, the insulation resistance of a 1m long sample is 1000MΩ;The insulation resistance of the 10m long sample is 100MΩ;
7. The diameter and material of the sheathed thermocouple wire
Thermocouple wire form | Single | Double support | |
Diameter of casing | Ф2Ф3 Ф4 Ф5 Ф6 Ф8 | Ф3Ф4 Ф5 Ф6 Ф8 | |
Material of casing | E﹑J﹑T | 1Cr18Ni9Ti | 1Cr18Ni9Ti |
K﹑N | 1Cr18Ni9Ti GH3030 | 1Cr18Ni9Ti GH3030 | |
S | GH3039 | GH3039 |
8. Installation and fixing form of armored thermocouple
9. Junction box form of armored thermocouple
10. The recommended operating temperature of the armored thermocouple
Variety | Casing material | Outer diameter | Operating temperature (°C) | |
long-term use | Short-term use | |||
镍铬-镍硅 | 1Cr18Ni9Ti | 2.0 | 600 | 700 |
3.0,4.0,5.0,6.0,8.0 | 800 | 900 | ||
GH3030 | 2.0,3.0 | 800 | 900 | |
4.0,5.0 | 900 | 1000 | ||
6.0,8.0 | 1000 | 1100 | ||
Nickel Chromium Silicon-Nickel Silicon | 1Cr18Ni9Ti | 2.0 | 600 | 700 |
3.0,4.0,5.0,6.0,8.0 | 800 | 900 | ||
GH3030 | 2.0,3.0 | 900 | 1000 | |
4.0,5.0 | 1000 | 1100 | ||
6.0,8.0 | 1100 | 1200 | ||
GH3039 | 2.0,3.0,4.0 | 1000 | 1100 | |
5.0,6.0,8.0 | 1100 | 1200 | ||
Nickel Chromium-Copper Nickel | 1Cr18Ni9Ti | 2.0 | 500 | 600 |
3.0,4.0,5.0 | 600 | 700 | ||
6.0,8.0 | 700 | 800 | ||
Iron-Copper Nickel | 1Cr18Ni9Ti | 2.0 | 400 | 500 |
3.0,4.0,5.0 | 500 | 600 | ||
6.0,8.0 | 600 | 750 | ||
Copper-Copper Nickel | 1Cr18Ni9Ti | 2.0,3.0,4.0,5.0 | 250 | 300 |
6.0,8.0 | 300 | 350 | ||
Platinum Rhodium 10-Platinum | GH3039 | 2.0,3.0,4.0 | 1000 | 1100 |
5.0,6.0,8.0 | 1100 | 1200 |
11. Model naming method of armored thermocouple