60V AC Resetable Fuse Schaltbild
- PRODUCT DETAIL
Application: for line voltage power supply, transformers and other electrical products
Features: Low operating current, radial lead package products
For 250VAC the following circuit protection
Operating current: 0.02A ~ 2A
Maximum working voltage: 250VDC
Operating temperature range: -40 ℃ to 85 ℃
Lead-free, halogen-free environmentally friendly products, RoHS and REACH standards

Features: Low operating current, radial lead package products
For 250VAC the following circuit protection
Operating current: 0.02A ~ 2A
Maximum working voltage: 250VDC
Operating temperature range: -40 ℃ to 85 ℃
Lead-free, halogen-free environmentally friendly products, RoHS and REACH standards

Sign | Definition |
Ih | Hold current-maximum current at which the device will not trip at 25℃ |
It | Trip current-minimum current at which the device will always trip at 25℃ |
Vmax | Maximum voltage at which the device will not trip |
Vmaxi | Maximum voltage device can withstand without damage at it rated current |
Imax | Maximum fault current device can withstand without damage at rated voltage |
Rmin | Minimum device resistance at 25℃ prior to tripping |
Rmax | Maximum device resistance at 25℃ prior to tripping |
Figure | The Figure of PTC |
Lead | Lead diameter |